ACR Index Get a draft ACR

Visual Studio 2022

Accessibility Conformance Report published by Microsoft

Conformance by level

Reported by the vendor. WCAG Level AA is the benchmark referenced by ADA Title II, Section 508 and the European Accessibility Act; Level AAA is optional and often left unevaluated.

Source: Download the original report from Microsoft (Word document). Or browse all of Microsoft's reports on Microsoft's own site.

These figures are extracted from that document. They are the vendor's own statements, not an independent assessment, and automated extraction can misread a table.

All reported criteria (50)

Conformance as stated by Microsoft in its published report.
CriterionNameLevel ConformanceRemarks from vendor
1.1.1 Non-text Content A Supports
1.2.1 Audio-only and Video-only (Prerecorded) A Not Applicable
1.2.2 Captions (Prerecorded) A Not Applicable
1.2.3 Audio Description or Media Alternative (Prerecorded) A Not Applicable
1.2.4 Captions (Live) AA Not Applicable
1.2.5 Audio Description (Prerecorded) AA Not Applicable
1.3.1 Info and Relationships A Partially Supports When a “No Symbol Loaded” page is shown when the user hits a break, the user can add path to the symbol search path box. There are suggestions in the dropdown when the user types in the path. However, screen reader doesn’t announce the suggestions. The users who rely on screen reader will not get notified about the notification. However, users can use arrow up/down keys to navigate the suggestions in the dropdown. Screen reader will announce the item.While creating a Service Fabric cluster and navigating through the advance tab using caps lock + arrow key, Narrator does not announce the text available on the screenThere are a few different accessibility issues in “Tools” -> "Options" -> “Debugging” -> “Output Window” page. For example, when the focus is at the name of the option, Narrator announces the control type as “Button”, which is not really a button. When the focus is at the value and the user changes the value, Narrator doesn’t announce the new value. The keyboard navigation isn’t intuitive. The user has to focus on the name of the option before moving to the next option.There are several different accessibility issues with the Pull Members Up dialog, which is a new Roslyn code refactoring. For instance, screen readers would read internal namespace information for members listed in the dialog.Screen reader doesn't read the second column in Autos, Locals, and Watch window.In the Parallel Stacks window, the Method View visualization of the window does not allow proper navigation via keyboard and screen readers will give false relationship data.In Cloud Service projects, in the Diagnostics Configuration dialog, some screen readers may not announce when a radio button is selected or unselected.While using Quick Actions in the XAML Designer, Narrator may not announce some of the text information present in the popup.When expanding the Action Button in the ASP.net connected services experience, NVDA may repeat some messages multiple times.
1.3.2 Meaningful Sequence A Partially Supports When the user uses advanced navigation in Narrator on the table in the Modules window, the Narrator focus is not logical while navigating using CAPS+Arrow keys.When the user uses Narrator in scan mode on Autos, Locals, and Watch window, Narrator doesn't read the content in a meaningful way.
1.3.3 Sensory Characteristics A Supports
1.3.4 Orientation AA Supports
1.3.5 Identify Input Purpose AA Supports
1.4.1 Use of Color A Partially Supports In the Diagnostics Hub Events Viewer Tool, the color contrast ratios between the stacked bars in the bar chart are less than 3:1. Users with visual acuity issues may have issues perceiving the data visualizations in the graph. The suggested workaround is to use the graph data cursor to navigate the stacked bar graph, using either the mouse or the left/right arrow keys.
1.4.2 Audio Control A Not Applicable
1.4.3 Contrast (Minimum) AA Partially Supports Some icons on the VSTO FormRegion wizard do not meet High Contrast Standards
1.4.4 Resize text AA Supports
1.4.5 Images of Text AA Supports
1.4.10 Reflow AA Partially Supports Users who attempt to interact with Visual Studio at an effective resolution below the Visual Studio stated minimum requirements (1280x720) may experience truncated UI or other visual issues.
1.4.11 Non-Text Contrast AA Supports
1.4.12 Text Spacing AA Supports
1.4.13 Content on Hover or Focus AA Does Not Support Tooltips in Visual Studio do not currently support content on Hover or Focus.
2.1.1 Keyboard A Partially Supports Inserting controls from the toolbox to the Xamarin Forms Previewer/Code Editor is not currently possible with only a keyboard.It is not currently possible to obtain keyboard focus on the Platform, Device, Orientation and Zoom controls on the Xamarin Forms Previewer.In many cases in Visual Studio, users cannot use keyboard to show the tooltip of a control. While inspecting a performance report from the profiler, users are not able to use the keyboard to navigate to all of the elements in the report. Screen reader users will have difficulty determining all the contents of the report.Users who rely on the Data Source selector for Web Forms may encounter issues with selecting an OLE DB provider
2.1.2 No Keyboard Trap A Partially Supports While inspecting the Performance Tools options in the Tools -> Options dialog , users cannot use the Tab or Arrow keys exclusively to navigate the elements of the window and focus order is not consistent between Tab and Arrow keys. Screen reader users may not be able to determine the flow of the window.While inspecting a performance violation in an IntelliTrace file with performance data, users cannot use SHIFT+TAB to get out of the call tree once the focus is set on it. This is a keyboard trap for users with visual impairments who will find it difficult to navigate back from the call tree. However, the user can use TAB to get out of the call tree.Some users of the Xamarin Property Panel may experience a keyboard focus trap when navigating away from the search properties text view via tab navigation.
2.1.4 Character Key Shortcuts A Supports
2.2.1 Timing Adjustable A Not Applicable
2.2.2 Pause, Stop, Hide A Not Applicable
2.3.1 Three Flashes or Below Threshold A Supports
2.4.1 Bypass Blocks A Not Applicable
2.4.2 Page Titled A Not Applicable
2.4.3 Focus Order A Partially Supports The keyboard focus is not correct in the Select Data Source Window Keyboard focus order is incorrect under the Debug tab in the project properties window. The focus loops within the Debug tab.Users navigating the WinForms Designer Options may not be notified when the drop down for "Auto Load Controls in the ToolBox" has focus. Be advised that the user may use the keyboard up/down arrows to cycle through the available options when the text in the corresponding text box is selected.In the Containers tool window, focus order may not be logical for some controls.
2.4.4 Link Purpose (In Context) A Supports
2.4.5 Multiple Ways AA Not Applicable
2.4.6 Headings and Labels AA Supports
2.4.7 Focus Visible AA Partially Supports Keyboard focus is not visible in the "Look in" list items pane When opening a memory heap analysis window from either the Diagnostic Tool Window's memory tool or the Debug Managed Memory dump debugging feature, the initial keyboard focus is set to a parent container that has the narrative text of the path to a file on disk. This will also happen when selecting a snapshot to diff against, or when the user tabs off of the last element in the view. This focus element can be disorienting to users, as they are not alerted to where the tool has taken them. In the meantime, pressing tab will return focus to the tool as expected.While inspecting a performance report from the profiler, the focus indicator can be lost when placed on elements in the report. Users who rely on the keyboard to operate the report will have difficulty determining the component on which keyboard operations will interact.
2.5.1 Pointer Gestures A Supports
2.5.2 Pointer Cancellation A Supports
2.5.3 Label in Name A Supports
2.5.4 Motion Actuation A Supports
3.1.1 Language of Page A Supports
3.1.2 Language of Parts AA Not Applicable
3.2.1 On Focus A Supports
3.2.2 On Input A Supports
3.2.3 Consistent Navigation AA Not Applicable
3.2.4 Consistent Identification AA Supports
3.3.1 Error Identification A Supports
3.3.2 Labels or Instructions A Supports
3.3.3 Error Suggestion AA Supports
3.3.4 Error Prevention (Legal, Financial, Data) AA Supports
4.1.1 Parsing A Partially Supports While inspecting a .NET allocation profiling report, users who rely on Narrator will not be able to interact with the application after unchecking/checking a context menu item.
4.1.2 Name, Role, Value A Partially Supports Some tree controls in Visual Studio do not correctly announce when node elements are expanded or collapsed with the keyboard, even if the operation is completing successfully.Some controls on the Xamarin Forms Previewer do not have names that can be programmatically determined.Users who rely on Assistive Technologies may have difficulties using the Table Adapter Configuration Wizard. Some elements of the Xamarin Property Panel have children with non-unique names and may be difficult to differentiate for visually-impaired users. Users who rely on Assistive Technologies may have difficulties using Workflow Designer Property Panel.Users who rely on Assistive Technologies may have difficulties using the Query Builder dialog.Users who rely on Assistive Technologies may have difficulties using the Access Permission list items on the Data Link Properties dialog.Users who rely on Assistive Technologies may have difficulties using Table Adapter Configuration Wizard.Users who rely on Assistive Technologies may have difficulties using Data Source Configuration Wizard.While inspecting a performance report from the profiler, some UI elements have poor values for accessibility properties. Data tables in the report aren't defined as tables, and expandable items in the report aren't defined as expandable, for example. Screen reader users will be unable to determine the state or nature of all the elements in the report.While inspecting the Diagnostic Tools window, focus can be set to one of two invisible elements in the window which both have long values for the Name property of each element. The values in each Name property include the full path to a file on disk ("file://C:\Program Files (x86)\Microsoft Visual Studio\2017\Enterprise\Common7 \IDE\CommonExtensions\Platform\ DiagnosticsHub\WebViews \PerformanceDebugger SwimLanesView.html" for example). Screen readers will ready the lengthy text of the Name property which is not related to the contents of the window. While inspecting a performance report from the profiler, some UI elements have poor values for accessibility properties. Data tables in the report aren't defined as tables, and expandable items in the report aren't defined as expandable, for example. Screen reader users will be unable to determine the state or nature of all the elements in the report.In debugging, the user can inspect the Thread window. But user using screen reader won’t know that the row is about a process group instead of a thread. Besides, there is a button to expand/collapse the threads that belong to the process. Screen reader doesn’t announce what the button is for. The button doesn’t have the property IsExpandCollapsePatternAvailable. Users using assistive technology won’t know that they can expand or collapse the threads.Users who rely on Assistive Technologies may have difficulties using the ASP.NET ListViewControlThe WinForms Property Browser ToolStrip contains buttons to change the layout of the Property Browser from categorized to alphabetized and from control properties to control events. Visually impaired users may not be able to determine the state of these toggle buttons and will need to enter the Property Browser to determine its layout.Disabled text may be difficult to read when setting up data binding properties of WinForms controls in the Formatting and Advanced Binding Dialog of the WinForms Designer when the user is in High Contrast Mode. Multiple controls in this page are not using the disabled text color provided by the Operating System.Visual Studio Installer experience has known issues when used with Narrator.
4.1.3 Status Messages AA Supports

Is this your product? If this report is out of date or misrepresented, we will correct or remove it. Contact us to claim this listing.

Get told when this changes

This report is dated December 2, 2021. An ACR can be quietly replaced at any time, and the published date is the only signal a buyer gets. We will email you when this one is updated.

Double opt-in — we email you once to confirm, and send nothing until you do. One-click unsubscribe on every message. We store your address and what you are watching, nothing else. Privacy.